User Settings
Open AccessArticle

New immunohistochemical "sandwich" staining method for mdr1 P-glycoprotein detection with JSB-1 monoclonal antibody in formalin-fixed, paraffin-embedded human tissues.

47

TL;DRAbstract

We have developed a new immunoperoxidase "sandwich" staining method for amplified detection of P-glycoprotein (Pgp) that is suitable for use on formalin-fixed, paraffin-embedded (conventional) tissue sections. This was accomplished by substantially changing the procedure described by Chan (1988) so as to increase specific staining intensity and to decrease nonspecific background staining. To determine the most appropriate primary antibody for the assay, we compared the immunoreactivity of JSB-1, C494, and C219 monoclonal antibodies recognizing internal epitopes of Pgp, and MRK16 and 4E3 monoclonal antibodies recognizing external epitopes of Pgp. Paraffin sections of Pgp-positive normal human tissues (adrenal, liver, kidney, and brain), of renal tumors, and of cell pellets of sensitive and multidrug resistant human tumor cell lines (MCF-7, KB) were used for comparisons. Immunostaining was excellent with JSB-1, moderate with C494, and very weak with C219. MRK16 and 4E3 showed no reaction

Chat with Paper

AI Agents for this Paper

We have developed a new immunoperoxidase "sandwich" staining method for amplified detection of P-glycoprotein (Pgp) that is suitable for use on formalin-fixed, paraffin-embedded (conventional) tissue sections. This was accomplished by substantially changing the procedure described by Chan (1988) so as to increase specific staining intensity and to decrease nonspecific background staining. To determine the most appropriate primary antibody for the assay, we compared the immunoreactivity of JSB-1, C494, and C219 monoclonal antibodies recognizing internal epitopes of Pgp, and MRK16 and 4E3 monoclonal antibodies recognizing external epitopes of Pgp. Paraffin sections of Pgp-positive normal human tissues (adrenal, liver, kidney, and brain), of renal tumors, and of cell pellets of sensitive and multidrug resistant human tumor cell lines (MCF-7, KB) were used for comparisons. Immunostaining was excellent with JSB-1, moderate with C494, and very weak with C219. MRK16 and 4E3 showed no reaction

Keywords

ImmunostainingImmunoperoxidaseMonoclonal antibodyStainingImmunohistochemistryPathologyPrimary and secondary antibodiesBiology

Chat

Click to start Chat