CitedEvidence
User Settings
Article

Removal of Aqueous Phase Petroleum Products in Groundwater by Aeration

G. B. Wickramanayake,Arthur, M. F.,A.J. Pollack,K. Saravanakumar-1992-06-01-Defense Technical Information Center (DTIC)
1

TL;DRAbstract

This study evaluated the effectiveness of conventional air stripping for removal of jet fuels (JP-5 and AVGAS) from groundwater, using samples collected near the Patuxent River Naval Air Station fuel farm in NM. Using an air flow rate of 0.3 L/min, fuel contaminants (a mixture of JP-3 and AVGAS) were removed in excess of 97% within 30 minutes. At the same flow rate, 96% of a less volatile fuel contaminant (primarily JP-3) was removed in 30 minutes. These results indicate that even low volatility jet fuel can be removed from groundwater to low levels (<2 mg/L) by air stripping. Iron precipitation during aeration of groundwater could plug packed-bed air strippers unless pre-aeration and iron precipitate removal was implemented before packed-bed air stripping.

Chat with Paper

AI Agents for this Paper

This study evaluated the effectiveness of conventional air stripping for removal of jet fuels (JP-5 and AVGAS) from groundwater, using samples collected near the Patuxent River Naval Air Station fuel farm in NM. Using an air flow rate of 0.3 L/min, fuel contaminants (a mixture of JP-3 and AVGAS) were removed in excess of 97% within 30 minutes. At the same flow rate, 96% of a less volatile fuel contaminant (primarily JP-3) was removed in 30 minutes. These results indicate that even low volatility jet fuel can be removed from groundwater to low levels (<2 mg/L) by air stripping. Iron precipitation during aeration of groundwater could plug packed-bed air strippers unless pre-aeration and iron precipitate removal was implemented before packed-bed air stripping.

Keywords

AerationAir strippingEnvironmental scienceGroundwaterStripping (fiber)PrecipitationEnvironmental engineeringPacked bed

Chat

Click to start Chat