Demonstration tests on PWR steam generator tube-tubesheet crevice flushing procedures
TL;DRAbstract
A series of autoclave tests was completed to evaluate the effectiveness of a flushing technique for removal of contaminants from a simulated nuclear steam generator tube-tubesheet crevice. All testing was performed using a depressurization technique under various conditions to determine the removal efficiency of caustic in open and, in one case, a packed simulated tubesheet crevice. Flushing by depressurization was found to remove substantial portions of NaOH from open and packed crevices. Additional work is required for optimizing these techniques.
Chat with Paper
AI Agents for this Paper
A series of autoclave tests was completed to evaluate the effectiveness of a flushing technique for removal of contaminants from a simulated nuclear steam generator tube-tubesheet crevice. All testing was performed using a depressurization technique under various conditions to determine the removal efficiency of caustic in open and, in one case, a packed simulated tubesheet crevice. Flushing by depressurization was found to remove substantial portions of NaOH from open and packed crevices. Additional work is required for optimizing these techniques.