TL;DRAbstract

The deposition kinetics of copper from perchloric solutions on Cd electrode have been studied by polarographic technique. The copper ions depletion follows a first order law: the kinetics constant is $0,5.10^-^5$ $moles.sec^-^1.cm^-^2$ for Cu deposition on fresh Cd electrodes, and $1.10^-^5 moles.sec^-^1.cm^-^2$ for deposition and previously corroded Cd electrodes.

Chat with Paper

AI Agents for this Paper

The deposition kinetics of copper from perchloric solutions on Cd electrode have been studied by polarographic technique. The copper ions depletion follows a first order law: the kinetics constant is $0,5.10^-^5$ $moles.sec^-^1.cm^-^2$ for Cu deposition on fresh Cd electrodes, and $1.10^-^5 moles.sec^-^1.cm^-^2$ for deposition and previously corroded Cd electrodes.