In-reactor measurement of fuel element cladding temperatures

D.R. Doman-1960-04-08
0

TL;DRAbstract

A design was developed for leading thermocouples from a high-temperature, pressurized water reactor-coolant system of such integrity that no reactor shutdowns were caused by its use. Using this design, measurements of the fuel-element-cladding temperature and its variation with time were made in three tests on elements clad in type X-8001 aluminum alloy. The following conclusions were reached from the test results: (1) the cladding temperature of a fuel element operated at low heat flux in high bulk-outlet temperature water did not increase with time and was slightly lower than predicted by the Sieder-Tate equation; (2) cladding temperatures of fuel elements operated at high heat flux in either high bulk-inlet or outlet temperature water increased 40 C higher than predicted by the Sieder-Tate equation with initial temperatures equal to the predicted temperatures; and (3) the rate of temperature increase appeared dependent only on fuel-element heat flux and location with respect to the

Chat with Paper

AI Agents for this Paper

A design was developed for leading thermocouples from a high-temperature, pressurized water reactor-coolant system of such integrity that no reactor shutdowns were caused by its use. Using this design, measurements of the fuel-element-cladding temperature and its variation with time were made in three tests on elements clad in type X-8001 aluminum alloy. The following conclusions were reached from the test results: (1) the cladding temperature of a fuel element operated at low heat flux in high bulk-outlet temperature water did not increase with time and was slightly lower than predicted by the Sieder-Tate equation; (2) cladding temperatures of fuel elements operated at high heat flux in either high bulk-inlet or outlet temperature water increased 40 C higher than predicted by the Sieder-Tate equation with initial temperatures equal to the predicted temperatures; and (3) the rate of temperature increase appeared dependent only on fuel-element heat flux and location with respect to the

Keywords

ThermocoupleCladding (metalworking)Materials scienceCoolantHeat fluxNuclear engineeringFlux (metallurgy)Alloy

Chat

Click to start Chat