150-m measurement of 0. 880- to 100. 0-keV neutron transmissions through four samples of /sup 238/U
TL;DRAbstract
In order to study the /sup 238/U + n total cross section, neutron transmissions through 0.076-, 0.254-, 1.080-, and 3.620-cm-thick samples of isotopically enriched /sup 238/U have been measured from 0.880 to 100.0 keV using a time-of-flight technique over a path length of 150 meters with the ORELA pulsed source and a 13-mm-thick Li-glass detector. The measurement is described in detail and both a listing and figures of the resulting transmissions are given. An absolute energy scale accurate to 2 parts in 10,000 was established.
Chat with Paper
AI Agents for this Paper
In order to study the /sup 238/U + n total cross section, neutron transmissions through 0.076-, 0.254-, 1.080-, and 3.620-cm-thick samples of isotopically enriched /sup 238/U have been measured from 0.880 to 100.0 keV using a time-of-flight technique over a path length of 150 meters with the ORELA pulsed source and a 13-mm-thick Li-glass detector. The measurement is described in detail and both a listing and figures of the resulting transmissions are given. An absolute energy scale accurate to 2 parts in 10,000 was established.